Installing a 100A 3-pole breaker from ABB requires careful planning, attention to detail, and adherence to safety guidelines. Here's a step-by-step guide to help you through the process:

Pre-installation checks:

  1. Verify the electrical panel rating: Ensure the main electrical panel is rated for 100A and has sufficient space for the new breaker.
  2. Check the wiring: Verify that the wiring in the panel is suitable for 100A and meets the National Electric Code (NEC) requirements.
  3. Turn off the power: Switch off the main electrical power at the circuit breaker or fuse box to prevent accidental start-ups or electrical shocks.

Installation steps:

  1. Remove the existing breaker (if applicable): Take out the old breaker and disconnect the wires from the busbar.
  2. Identify the correct busbar: Determine which busbar the new breaker will be installed on. Typically, 3-pole breakers are installed on the middle or top busbar.
  3. Connect the wires: Connect the wires to the new breaker according to the manufacturer's instructions and the NEC. Ensure the wires are securely attached and meet the required torque specifications.
  4. Install the breaker: Place the new 100A 3-pole breaker onto the busbar, ensuring it is securely seated and the terminals are aligned with the wires.
  5. Tighten the breaker: Tighten the breaker's mounting screws or clips according to the manufacturer's instructions.
  6. Verify the breaker's position: Double-check that the breaker is properly seated and the wires are not damaged or pinched.
  7. Test the breaker: Turn the power back on and test the breaker by tripping it manually (if possible) or by applying a load to the circuit. Verify that the breaker trips correctly and the circuit is de-energized.

Additional considerations:

  1. Grounding: Ensure the grounding system is properly connected and meets the NEC requirements.
  2. Arc fault protection: If the circuit requires arc fault protection, ensure the breaker is equipped with this feature or install an arc fault circuit interrupter (AFCI) device.
  3. Labeling: Label the breaker and the circuit to indicate the 100A rating and the type of load it serves (e.g., residential, commercial, or industrial).
  4. Inspection and testing: Perform a thorough inspection and testing of the electrical system to ensure it is safe and functioning correctly.

Important safety notes:

  1. Work with a licensed electrician: If you're not experienced in electrical work, it's recommended to hire a licensed electrician to perform the installation.
  2. Follow safety guidelines: Always follow proper safety guidelines when working with electrical systems, including wearing personal protective equipment (PPE) and ensuring the work area is well-lit and clear of hazards.
  3. Comply with local regulations: Familiarize yourself with local electrical codes and regulations, and ensure the installation meets all applicable standards.

Remember to always prioritize safety and follow proper installation procedures when working with electrical systems. If you're unsure about any aspect of the installation, consult a licensed electrician or the ABB manufacturer's instructions.